The horizontal sterilization retort operation method

The horizontal sterilization retort operation method
Keywords: ,

Now Sterilization retort is most of the horizontal, the factory is the most common type of sterilization retort, horizontal sterilization retort is relative to vertical sterilization retort said. Vertical sterilization retort in and out of the material in the vertical space, very inconvenient, often need a crane. Of course, except it is a very light weight product. And the horizontal sterilization retort is a lot of convenience. Horizontal sterilization retort is in the plane direction of the material, the product into the sterilization plate or sterilization basket, through the turnover cart is easy to enter and exit the sterilization retort.


In terms of heat distribution, the horizontal sterilization retort is definitely much better than the vertical one.


Horizontal high temperature sterilization retort operation is very simple:

Confirm sterilization conditions: before sterilization must confirm sterilization conditions have been available, such as whether the boiler steam pressure is in line with. Whether the cooling water of the cool water tank is enough and whether the water temperature meets the requirement. Whether the compressed air pressure is sufficient.

Filling products: Products push to the door of the sterilization retort with a trolley, and then open the retort door to promote the product sterilization retort.

Closed retort door: pull the big unicom handle, cut off the pot door and the outside of the pot. There is a sealing switch at the door of the sterilization pot, generally need to manually twist 90° (automatic pipeline automatic), compressed air into the sealing ring sterilization pot door.

Sterilization formula: Set sterilization temperature, such as 121°C. Set a time limit, like 25 minutes.

Heat up the sterilizer: Turn on the circulating pump, open the inlet steam valve, and heat up to the specified temperature, like 121°C

Keep the sterilizer temperature for a specified time, like 25 minutes.

Sterilization pot cooling: open the water pump, into the cool water cooling, cooling for about 20 minutes, the cool water discharged.

Sterilization pot product pressure relief pot: open the unicom valve thorough pressure relief, open the pot door, pull out the product.